Göktürk Seyhan

Leaf VPD Calculator

Air and leaf conditions
Air temperature (°C)
Relative humidity (%)
Leaf temperature
Leaf − air temperature (°C)Transpiring leaves under LEDs run 0.5–2 °C cooler than the air; under HPS or sun they can be 1–3 °C warmer.
Leaf temperature (°C)From an IR thermometer or thermal camera.
Leaf VPD
—kPa
Air VPD—
Saturation vapour pressure, air—
Saturation vapour pressure, leaf—
Actual vapour pressure—
Dew point—
RH at leaf temperature—

Reaching a target
Target leaf VPD (kPa)
Humidity needed at current temperatures—
Leaf temperature needed at current humidity—
Air temperature needed at current RH and leaf offset—
Typical targets by crop stage

Click a row to use it as the target.

StageLeaf VPDNotes
Cuttings, seedlings, germination0.4–0.8 kPaLittle root; keep transpiration low
Leafy greens and herbs0.6–1.0 kPaTip-burn risk rises with high VPD and fast growth
Vegetative growth0.8–1.2 kPaSteady transpiration and nutrient transport
Flowering and fruiting1.2–1.5 kPaTomato, pepper, cannabis; less disease pressure
Late flowering, ripening1.3–1.6 kPaDry canopy against botrytis

Below ≈ 0.4 kPa the canopy stays wet, transpiration and calcium transport stall and moulds thrive. Above ≈ 1.6 kPa stomata close, photosynthesis drops and leaves may scorch.

Leaf VPD chart
< 0.4 too humid0.4–0.8 propagation0.8–1.2 vegetative1.2–1.6 generative> 1.6 too dry

Air temperature across, relative humidity up, coloured by leaf VPD with the current leaf-to-air difference. Move the pointer over the chart to read values.

How it works
es(T) = saturation vapour pressure at T (Hyland–Wexler, ASHRAE)
ea = RH · es(Tair)
VPDair = es(Tair) − ea
VPDleaf = es(Tleaf) − ea

Vapour pressure deficit is the difference between how much water vapour the air could hold and how much it actually holds. Transpiration is driven by the gradient between the saturated air inside the leaf, at leaf temperature, and the surrounding air — so the leaf VPD is the value that matters to the plant. Air VPD from a wall-mounted sensor is only a proxy: a leaf 2 °C cooler than 24 °C air at 65% RH sees a VPD about 0.25 kPa lower than the sensor reports.

Saturation pressure rises roughly 6–7% per °C, so each degree of leaf-to-air difference shifts the VPD by about that share of es — the Tetens form es = 0.6108 · exp(17.27 T ⁄ (T + 237.3)) agrees with the formulation used here to within 0.1% between 0 and 50 °C.

Background on measuring leaf-level VPD directly: Seyhan & Seyhan (2026), Real-Time Leaf-Level Vapor Pressure Deficit Monitoring, Applied Sciences 16(17), 8625.